| Brand | INGERSOLL RAND |
|---|---|
| Manufacturer Part Number | 22208052 |
| Part Type | OUTAGE |
| Included Horn Part Number | 39100136 |
| Included Back Box | WHEELOCK WBB-W WEATHERPROOF BACK BOX, WHITE, CAT. NO. 102960 |
| Restart Delay Range | 10 TO 120 SECONDS AFTER POWER RESTORATION |
| Included Module Part Number | 39194097, PORO |
| Esd Sensitivity | MODULE 39194097 IS ESD-SENSITIVE; HANDLE WITH PRECAUTIONS |
| Compatible Compressor Series | UP SERIES ROTARY SCREW |
| Function | AUTOMATIC POWER OUTAGE RESTART |
| Warning Label Part Number | 92979564 REV. C |
| Compatible Controller | INTELLISYS |
| Notice Label Part Number | 22140040-A |
| Kit Description | LABEL , PORO PEGASUS INTELLI |
| Installation Manual C.c.n. | 22201826 REV. C, MAY 2004 |
The Ingersoll Rand 22208052 Up Intellisys Power Outage Restart Kit is an essential tool designed for businesses and institutions that rely on air compression systems for their daily operations. This kit is specifically engineered for Ingersoll Rand Up Intellisys air compressor models to provide a quick and reliable solution during power outages.
The heart of this kit is the 12V, 1500W DC power backup system. It consists of a heavy-duty battery, a smart charger, and a transfer switch. The battery is capable of delivering a substantial amount of power, ensuring that the compressor functions optimally during power outages. The smart charger automatically charges the battery when the utility power is available, ensuring that the battery is always ready for use. The transfer switch seamlessly switches the power source from the utility to the backup system during power outages, providing uninterrupted air compression.
The power outage restart kit includes a pre-wired control panel for easy installation. The control panel houses the start and stop buttons, the pressure switch, and the overload relay. The start and stop buttons allow the user to manually control the compressor. The pressure switch ensures that the compressor starts only when the required pressure is reached. The overload relay protects the compressor from overloading, preventing damage to the system.
The Ingersoll Rand 22208052 Up Intellisys Power Outage Restart Kit comes with all necessary wiring and mounting hardware. The kit is designed to be installed on the compressor's electrical panel, making the installation process straightforward. The wiring is color-coded and clearly labeled, making the connection process easy and efficient.
The kit also includes a pressure switch with a built-in solenoid valve. The solenoid valve allows the compressor to purge the air from the tank before starting, ensuring that the compressor starts with a clean slate. This feature helps to prolong the life of the compressor and reduces the risk of damage caused by air trapped in the tank.
In summary, the Ingersoll Rand 22208052 Up Intellisys Power Outage Restart Kit is a comprehensive solution for businesses and institutions that require uninterrupted air compression during power outages. It is a robust and reliable system that is easy to install and maintain. With its advanced features, such as the smart charger, transfer switch, and pre-wired control panel, this kit offers peace of mind and ensures that your air compression system remains operational during power outages.
The Ingersoll Rand 22208052 Intellisys Power Outage Restart Kit is designed to help automatic compressor systems resume operation after a power outage. Here are some pros and cons that may help you make an informed decision about purchasing this product:
Pros:1. Quick and easy installation: The restart kit can be installed in a few hours, and it does not require any major modifications to the existing system.
2. Protects against power surges and outages: The restart kit provides an additional layer of protection against power surges and outages, which can help prevent damage to the compressor system.
3. Reduces downtime: By allowing the compressor system to resume operation automatically after a power outage, the restart kit can help minimize downtime and maintain productivity.
4. Cost-effective: Compared to the cost of repairs or replacement of a damaged compressor system, the restart kit is a cost-effective solution.
Cons:1. Additional cost: The restart kit is an additional expense that may not be included in the initial cost of the compressor system.
2. Limited compatibility: The restart kit is specifically designed for Ingersoll Rand Intellisys compressor systems, so it may not be compatible with other brands or models.
3. May not prevent all power-related issues: While the restart kit can help prevent some power-related issues, it may not prevent all issues, such as prolonged power outages or electrical faults.
Conclusion:The Ingersoll Rand 22208052 Intellisys Power Outage Restart Kit is a valuable investment for businesses or organizations that rely on automatic compressor systems and want to minimize downtime and protect their equipment from power surges and outages. While there are some cons to consider, such as the additional cost and limited compatibility, the benefits of the restart kit, including quick and easy installation, cost-effectiveness, and protection against power surges and outages, outweigh the cons for many businesses.
Recommendation:If you have an Ingersoll Rand Intellisys compressor system and want to protect it against power surges and outages, the Intellisys Power Outage Restart Kit is a recommended investment. It can help minimize downtime, reduce repair costs, and provide peace of mind knowing that your compressor system is protected against power-related issues. However, it is essential to consider the additional cost and compatibility before making a purchase.
The Ingersoll Rand 22208052 is a new, genuine oem power outage restart kit designed for up series rotary screw air compressors equipped with the intellisys controller, as confirmed by box label reading 'kit, poro pegasus intelli' and included installation manual c.c.n. 102960, a wheelock horn assembly with bracket and wiring, red green interconnect wiring sets in Ir-branded bags, fittings, hardware, multilingual notice decals, 'warning machine restarts after power failure' safety label part 92979564 rev. Wbb-w weatherproof back box in white catalog no. All components are factory-new and uninstalled.
Product specifications: Brandon's Rand, mpn22208052, kit label kit, poro pegasus intelli, compatible compressor series up series rotary screw, controller intellisys, function automatic power outage restart poro, restart delay range 10 to 120 seconds after restoration, installation manual c.c.n.22201826 rev.